SECTION 4 - MACHINE OPERATION

3121165

– JLG Lift –

4-23

2210 TRIGGER CLOSED TOO LONG WHILE IN

NEUTRAL

The trigger switch was closed for more
than five seconds while the joystick was
centered.

Check if the trigger switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

2232 FUNCTION PROBLEM - DRIVE & LIFT

BOTH OPEN

The drive and lift inputs are both de-ener-
gized in platform mode.

Check if either function is active, if Yes;

Refer problem to a qualified JLG mechanic.

2-3 Ground Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

231

FUNCTION PROBLEM - LIFT PERMA-
NENTLY SELECTED

The ground control box lift switch was
closed up or down, during power-up in
ground mode.

Check if the lift switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

232

GROUND LIFT UP / DOWN ACTIVE
TOGETHER

The lift up / down inputs are closed simul-
taneously.

Check if the lift switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

233

FUNCTION PROBLEM - BRAKE RELEASE
PERMANENTLY SELECTED

The manual brake release switch was
closed during power-up.

Check if the brake release switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

2-2 Platform Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK