SECTION 4 - MACHINE OPERATION

4-30

– JLG Lift –

3121165

423

LIFT UP AT CUTBACK - POWER MOD-
ULE CURRENT LIMIT

The lift up portion of the power module
has reached thermal limit.

Refer problem to a qualified JLG mechanic.

4-4 Battery Supply

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

441

BATTERY VOLTAGE TOO LOW - SYSTEM
SHUTDOWN

A problem has been detected with the bat-
teries or power module.

Recharge batteries or check for damaged batteries.
Check battery charger function.

Refer problem to a qualified JLG mechanic.

442

BATTERY VOLTAGE TOO HIGH - SYSTEM
SHUTDOWN

A problem has been detected with the bat-
teries or power module.

May be due to improper battery charging or incorrect voltage batteries

being used.

Refer problem to a qualified JLG mechanic.

443

LSS BATTERY VOLTAGE TOO HIGH

A problem has been detected with the load
sense system.

May be due to improper battery charging or incorrect voltage batteries

being used.

Refer problem to a qualified JLG mechanic.

444

LSS BATTERY VOLTAGE TOO LOW

A problem has been detected with the load
sense system.

Recharge batteries or check for damaged batteries.

Refer problem to a qualified JLG mechanic.

446

4421
4422

LOGIC SUPPLY VOLTAGE OUT OF RANGE The System Module logic supply voltage

was measured to be out of normal operat-
ing range.

Check for severely discharged battery, loose cables or for damaged bat-

tery; otherwise;

Refer problem to a qualified JLG mechanic.

4-2 Thermal Limit (SOA)

DTC

FAULT MESSAGE

DESCRIPTION

CHECK