1 tilt sensor, 1 tilt sensor -32, 7 electric motor – JLG 3246ES Operator Manual User Manual

Page 83

Advertising
background image

SECTION 4 - MACHINE OPERATION

3121165

– JLG Lift –

4-33

7710 PUMP P HIGH - CHECK POWER CIR-

CUITS

The power module detected a problem in
the drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.

7711 PUMP P LOW - CHECK POWER CIR-

CUITS

The power module detected a problem in
the drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.

7741 ARMATURE BRAKING CURRENT TOO

HIGH

The power module has detected excessive
braking current .

This can be caused by transporting an excessive load on a steep grade.

7742 FIELD VOLTAGE IMPROPER

The power module detected a problem in
the drive motors' power circuit wiring.

Recycle power on/off, if problem persists;
Refer problem to a qualified JLG mechanic.

7-7 Electric Motor

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

8-1 Tilt Sensor

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

811

TILT SENSOR NOT CALIBRATED

The tilt sensor calibration has not been
performed.

Refer problem to a qualified JLG mechanic.

812

NO DATA FROM TILT SENSOR - NOT
CONNECTED OR FAULTY

No signal from tilt sensor.

Refer problem to a qualified JLG mechanic.