6 rotator - helac, Disassembly, Rotator - helac -14 – JLG 601S Service Manual User Manual

Page 144: Disassembly -14, Removing portion of end cap -14, Heating setscrew -14, Removing setscrew -14, Removing end cap -14

Advertising
background image

SECTION 4 - BOOM & PLATFORM

4-14

– JLG Lift –

3120866

4.6 ROTATOR - HELAC

Disassembly

1. Place actuator on a clean workbench.

2. Remove all hydraulic fittings.

3. Using a suitable hammer and chisel remove the por-

tion of end cap securing setscrew.

4. Using a torch, apply heat to the setscrews on the

bottom of actuator.

5. Remove the two (2) setscrew (4) from bottom of

actuator (1). Discard setscrew.

6. Place two (2) 3/8"x16NC bolts in threaded holes in

bottom of the actuator. Using a suitable bar, unscrew
the end cap (5). Remove the end cap from actuator
(1).

Figure 4-18. Removing Portion of End Cap

Figure 4-19. Heating Setscrew

Figure 4-20. Removing Setscrew

Figure 4-21. Removing End Cap

Advertising