SECTION 1 - SPECIFICATIONS

1-2

– JLG Lift –

3120866

Swing System

Swing Motor Displacement - 75 cm[3] (4.62 cu. in.)

Swing Brake - Automatic spring applied hydraulically
released disc brakes.

Swing Hub Ratio - 50:1.

Hydraulic Gear Pump (at 1800 RPM)

7.9 GPM (29.90 lpm).

Pump Displacement - 16 cm[3] (1.02 cu. in.)

Clockwise Rotation.

Auxiliary Power Pump

9.84 lpm(2.6 GPM) @ 82.7 BAR (1200 PSI)

Pump Displacement - 14 cm[3] (.244 cu. in.)

DC Motor.

Clockwise Rotation.

Hydraulic Filter - In-line

Return - Bypass Type.

10 Microns Absolute.

Charge.

10 Microns Absolute.

Hydraulic Strainers (In Tank).

30 Microns.

1.3 PERFORMANCE DATA

Travel Speed.

4WD - 6.44 Km/hr. (4 mph)

Gradeability.

(4WD) 45%.

Turning Radius (Outside)

6.2 m (20 ft. 4.6 in.)

Turning Radius (Inside)

5.25 m (14 ft. 3.9 in.).

Boom Elevation

+18.36 m (60 ft. 2 13/16 in.) -1.87 m (6 ft. 1 11/16 in.).

Machine Weight approximately

10,211 kg (22,510 lbs.).

Machine Height (Stowed)

2.56 m (8 ft. 4.75 in.).

Machine Length (Stowed)

Over Drive Axle - 8.44 m (27 ft. 8.125 in.)

Machine Width

2WS/4WD - 2.42 m (7 ft. 11.4375 in.)

Wheel base

2.48 m (8 ft. 1.50 in.)

1.4 FUNCTION SPEEDS

Machine Orientation When Doing Speed

Tests

Lift: Telescope Retracted. Lift Up, Record Time, Lift Down,
Record Time.

Swing: Boom at Full Elevation. Telescope Retracted.
Swing the Turntable off center and stop. Swing the oppo-
site direction and start the test when the turntable is cen-
tered up. This eliminates ramp up and down on the
controller affecting times.

Telescope: Boom at Full Elevation; Telescope Retracted;
Telescope Out, Record Time. Telescope In, Record Time.

Drive (Forward/Reverse): Test should be done on a
smooth level surface. Drive Select Switch should be set to
High Engine. Start approximately 7.62 m (25 ft.) from the
starting point so that the unit is at maximum speed when
starting the test. Results should be recorded for a 60.96 m
(200 ft.) course. Drive Forward, Record Time. Drive
Reverse, Record Time.

Drive (Above Horizontal): Test should be done on a
smooth level surface. Drive Select Switch should be set to
Low Engine. The boom should be raised above horizon-
tal. Results should be recorded for a 15.24 m (50 ft.)
course. Drive Forward, Record Time. Drive Reverse,
Record Time.

Platform Rotate: Platform level and completely rotated
one direction. Rotate the opposite direction, Record Time.
Rotate the other direction, Record Time.

Articulating Jib: Platform level and centered with the
boom. Start with the Jib down. Jib Up, Record Time. Jib
Down, Record Time.



Advertising