Fuel valve lever, 4 outriggers, From the ground console – JLG T500J Operator Manual User Manual

Page 61: Fuel valve lever -7, Outriggers -7, From the ground console -7

Advertising
background image

SECTION 5 - MACHINE OPERATION

3121197

– JLG Lift –

5-7

Fuel Valve Lever

NOTE:

The fuel valve is turned off upon delivery and must be turned on
prior to use. The fuel valve should be turned off when machine is
not being used.

The fuel valve lever must be in the ON position for the engine to
run. When the engine is not in use, leave the fuel valve lever in
the OFF position to prevent carburetor flooding and to reduce
the possibility of fuel leakage.

5.4

OUTRIGGERS

THE OUTRIGGERS MUST BE SET BEFORE LIFTING CAN BEGIN.

ALWAYS UNHITCH FROM TOW VEHICLE PRIOR TO OPERATING OUTRIGGERS.

From the Ground Console

1.

Position the Platform/Ground Select switch to ground con-
trol.

2.

Engage and hold the function enable switch together with
the outrigger control switch.

3.

The lift is equipped with auto-level. When the lift reaches
level an alarm will sound with three short beeps indicating
that the lift is level. If the auto-level system does not operate
properly, DO NOT operate the machine; have the system
repaired by a qualified service technician.

Advertising
This manual is related to the following products: