SECTION 5 - MACHINE OPERATION

3121197

– JLG Lift –

5-11

2*

Drive & O/R Prevented - Operate From Platform
Drive & O/R Prevented - Place Boom On Rest
Drive & O/R Prevented - Set Hand Brake
Drive Prevented - Lift Down
Drive Prevented - Stow Outriggers
Drive Prevented - Telescope In
Lift Down Prevented - Tele In First
Lift Up & Tele Out Prevented - Tilted & Above Elevation
"Lift Up & Tele Out Prevented - Tilted, Unset,& Above Elevation "
Lift Up & Tele Out Prevented - Unset & Above Elevation
Lift Up Prevented - Check Outriggers
Lift Up Prevented - Lift Down Then Set Outriggers
Lift Up Prevented - Tilted
Model Changed - Hydraulics Suspended - Cycle EMS
Outrigger Stow Prevented - Tele In First
Outriggers Prevented - Elevated
Running At Creep - Tilted & Above Elevation
Running At Creep - Unset & Above Elevation
Tele Out Prevented - Set Outriggers
Tele Out Prevented - Tilted

Table 5-1. User Fault Codes

Code

Message

* A 2 user flash code indicates a problem with the machine set up, such as an outrigger not prop-
erly set. If this occurs while the boom is elevated, all functions will operate at a reduced speed.
Immediately return the platform to the stowed position and reposition the machine or reset the
outriggers, as required. If the problem still exists, troubleshoot with a JLG analyzer.

A 2 user flash code and tilt alarm warning indicator activated at the same time indicates a poten-
tial tipping condition. If this occurs while boom is elevated, the lift up and telescope out func-
tions will not operate. Telescope in, lift down and swing functions will operate at reduced speed.
THE BOOM MUST BE FULLY RETRACTED BEFORE LOWERING. Immediately return the platform to
the stowed position and reposition the machine or reset the outriggers, as required. If the prob-
lem still exists, troubleshoot with a JLG analyzer.

3

Battery Voltage Too High - System Shutdown
Battery Voltage Too Low - System Shutdown
No Charge System Output

4

Functions At Cutback - Power Module Current Limit
Power Module Too Hot - Please Wait

5

Battery Voltage Too High - System Shutdown
Battery Voltage Too Low - System Shutdown
Engine Not Running

9

Vehicle Requires Service

Table 5-1. User Fault Codes