SECTION 2 - PROCEDURES

3120743

– JLG Lift –

2-7

1. At battery connection, the LED should not illumi-
nate. At key ON, the LED should illuminate steadily. If
the LED illuminates and remains steady, but no
drive can be selected, contact JLG Service Depart-
ment.

2. 1 FLASH - Internal Fault. (Replace MOS90)

3. 2

FLASHES

- Procedure Fault. (Recycle Foot-

switch)
- Illegal start up sequence, 2 directions selected,
pump selected.
- Drive inhibited.
- Flashes until fault is cleared.

4. 3 FLASHES - Motor Permanently Low.
- Point ‘A’ < 7V in neutral, or < 7V for 15mS in
drive, or contactor coil short circuit or brake coil.

- Drive & pump inhibited.
- Recycle to neutral to clear.

Figure 2-1. Sevcon Controller Troubleshooting Flow

Charts. (Sheet 1 of 4).

5. 4 FLASHES - Motor Permanently High.
- Direction contactor welded. (Point ‘A’ within 6V
of B + ve in neutral).