SECTION 2 - PROCEDURES

3120743

– JLG Lift –

2-9

- Controller drives at minimum speed.
- Flashes in drive until fault cleared
.

8. 7 FLASHES - Low Battery Voltage - Battery Volt-
age < 13V.

- Drive inhibited.
- Recycle to neutral to clear flashes
.

Figure 2-1. Sevcon Controller Troubleshooting Flow

Charts. (Sheet 3 of 4).

9. 8 FLASHES - Thermal Cutback, Controller.
- Heat sink temperature > 80 degrees C (176
degrees F).