Code 33 - Both PHP Bars - UP

Code 38 - Battery Voltage Low - Warning Level 2 - Two (2) LED/LCDs lit

To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4
hours or until 8 bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level
2, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code. Failure to do so,
will result in a fault code 39.

Code 39 - Battery Voltage Low - Warning Level 3 - One (1) LED/LCDs lit

To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4
hours or until 8 bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level
1, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code.

Table 6-34. Code 33 - Both PHP Bars - UP

STEP

ACTION

SPEC

YES

NO

1.

Perform steps in Code 2, Left PHP Bar UP then, Code 3, Right PHP
Bar UP. Do either of these steps correct the problem?

Done

Go to Step 2

2.

Perform steps in Table 6-5 - Machine In Drive Speed Cut-Back (Tur-
tle) Mode All The Time
, of this section.

Done

Consult Factory