SECTION 6 - JLG CONTROL SYSTEM

6-22

– JLG Lift –

3121125

System Self Test

The system self test is utilized to locate typical problems.
See Table 6-6, System Test Descriptions and Table 6-7,
System Test Messages
for information concerning the
tests performed and available messages in this mode.

1. When the keys witch is in the platform position and

the self test enabled, the self test function will test all
valves, contactors, platform inputs, indicator lamps,
and system alarms for various fault conditions.

When the keys witch is in the ground position, the
self test function will test all valves, the line contac-
tor, ground control inputs, and the ground alarm out-
put for various fault conditions.

2. In order to test the inputs on the machine, the con-

troller will ask the service technician to perform vari-
ous tasks at the appropriate operator control station.
An example of this is “Close LLU Switch”. The con-
troller expects the operator to close the lower lift up
switch. When the controller sees that the lower lift up
switch has been closed, it will move on to the next
input, lower lift down LLD. If the switch is faulty or the
wiring is faulty, the controller will not move on to the

next input. The controller will continue to wait for the
closure of the input. If the operator knows the switch
is faulty and wants to continue the tests he must
simply press the enter key on the analyzer to con-
tinue.

3. After the controller has conducted the tests from the

chosen operator station, it will display “TESTS COM-
PLETE”. This indicates that the controller has
checked all inputs and outputs for that station.

IN ORDER FOR THE MACHINE TO FUNCTION AFTER THE SELF
TEST IS COMPLETE, POWER MUST BE RECYCLED USING THE
EMS OR THE KEY SWITCH.

TILT...

Displays measured vehicle tilt
The first value indicates tilt in die forwards reverse direction
(pitch)
The second value indicates tilt in the left/ right direction (roll)

DATALOG
MAX.TEMP...

Displays maximum measured heat sink temp.

MIN.TEMP...

Displays minimum measured heat sink temp.

MAX. BATTERY..

Displays maximum measured battery voltage

ON...

Displays total controller on (EMS) time

DRIVE...

Displays total controller drive operation time

PUMP...

Displays total controller pump running time
NOTE: includes all boom functions, steer and brake release

LIFT..

Displays total controller lift operation time

SWING...

Displays total controller swing operation time

TELE...

Displays total controller tell operation time

RENTAL...

Displays total controller operation time
NOTE: can be reset

ERASE RENTAL
YES:ENTER, NO:ESC ENTER

Not available at password level 2
Enter

resets rental datalog time to zero

VERSIONS
POWER

Displays power software version

PLATFORM

Displays platform software version

GROUND

Displays ground software version

POSITILT

Displays postulate software version

ANALYZER

Displays analyzer software version

Table 6-5. DIAGNOSTICS - Menu Descriptions