Table 6-1. Personality Ranges/Defaults

FUNCTION

PERSONALITY

RANGE

DEFAULTS

DRIVE

ACCELeration

0.5s to 5.0s

1.0

DECELeration

0.1s to 2.0s

0.5

MINimum speed

0 to 25%

3

MAXimum speed

0 to 100%

100

ELEVATED MAXimum speed

0 to 25%

20

CREEP MAXimum speed

0 to 45%

30

POSITRAC time

0 to 60s

10

POSITRAC current

50-250 A

170A

LOWER LIFT

ACCELeration

0.5 to 5.0s

1.0

DECELeration

0.0 to 3.0s

0.5

MINimum UP speed

0 to 30%

19

MAXimum UP speed

0 to 100%

95

MINimum DOWN speed

0 to 20%

7

MAXimum DOWN speed

0 to 100%

47

UPPER LIFT

ACCELeration

0.5 to 5.0

2.0

DECELeration

0.1 to 3.0

1.0

MlNimum UP speed

0 to 20

9

MAXimum UP speed

0 to 100

67

CREEP Maximum UP speed

0 to 50

30

MINimum DOWN speed

0 to 10

2

MAXimum DOWN speed

0 to 100

40

CREEP maximum DOWN speed

0 to 30

10

SWING

ACCELeration

0.5 to 5.0s

2.7

DECELeration

0.1 to 3.0s

1.8

MINimum LEFT speed

0 to 10%

1

MAXimum LEFT speed

0 to 60%

25

CREEP maximum LEFT speed

0 to 35%

15

MINimum RIGHT speed

0 to 10%

1

MAXimum RIGHT speed

0 to 60%

25

CREEP maximum RIGHT speed

0 to 35%

15