SECTION 3 - CHASSIS & TURNTABLE

3121125

– JLG Lift –

3-47

Battery Charging (On Board Charger)

1. For maximum battery life:

a. Avoid completely discharging the batteries.
b. Fully charge the batteries each day the machine

is used.

c. Charge the batteries at available times between

charging.

d. Be sure the battery fluid covers the battery

plates before charging, but to avoid overflow, do
not top off the fluid level until charging.

2. To charge the batteries, connect the charger to a

115 volt source with a 15 amp minimum capacity.

3. The Charger will shut off automatically when the bat-

teries are fully charged.

4. The charge cycle is complete when the ammeter

reads 0 amps. Any reading indicates the charge
cycle is not complete.

5. Depleted batteries will take approximately 17 hours

to charge.

Optional On Board Generator

EXHAUST GAS HAZARD. RUN THE GENERATOR IN A WELL VENTI-
LATED AREA ONLY.

WHEN THE GENERATOR ENABLE CONTROL LOCATED IN THE
PLATFORM CONTROL BOX IS IN THE ON POSITION AND THE
GROUND EMERGENCY STOP SWITCH IS ON (PULLED OUT), THE
GENERATOR WILL START AUTOMATICALLY WHEN THE BATTER-
IES REACH A LOW-CHARGE STATE, AUTOMATICALLY CHARGING
THE BATTERIES. THE GENERATOR WILL ALSO AUTOMATICALLY
START IF THE GENERATOR START BATTERY IS LOW.

NOTE: The engine will automatically shut down under the

following conditions:

High Engine Oil Temperature
Low Engine Oil Pressure
Engine Overspeed
Generator Over voltage
Batteries fully charged
Engine underspeed

TO AVOID INJURY FROM AN EXPLOSION, DO NOT SMOKE OR
ALLOW SPARKS OR A FLAME NEAR BATTERY DURING SERVIC-
ING. ALWAYS WEAR EYE AND HAND PROTECTION WHEN SER-
VICING BATTERIES.

Figure 3-19. Batteries and Battery Charger (Prior to S/N 0300059350)