6 INCH CHIPPER

15

4.2 conTrol arm oPeraTion

1. Start the chipper engine. Bring the chipper up to oper-

ating speed. See Section 3, "Controls and Operation,"

for starting, chipping and stopping instructions.

2. Engage the hydraulic feed by moving the control arm

as shown in Figure 4.2. In the forward direction, the

feed rate increases as the arm is moved.

3. Feed the branch (up to six inches in diameter).
4. If the chipper jams, reverse the feed by moving the

control arm in the reverse direction. Remove the branch

and rotate it before inserting it into the chute again.

Figure 4.1, Hydrostatic pump components

Feed Control
Lever

Forward

Reverse

Neutral

Figure 4.2, Control arm operation

4.1 hYdraulic feed insTrucTions

4.1.1 fluids
Premium hydraulic fluids containing high quality rust,

oxidation and foam inhibitors are required. These include

premium turbine oils, aPI CD engine oils per SaE J183,

M2C33F or g automatic transmission fluids meeting allison

C-3 or Caterpillar TO-2, and certain specialty agricultural

tractor fluids.

4.1.2 hYdrosTaTic PumP sTarT uP Procedure
Follow this start-up procedure when starting a new

installation or when restarting an installation in which the

hydrostatic pump has been removed from the system.
1. Before starting the hydrostatic pump, make sure all sys-

tem components (reservoir, fittings, etc.) are clean.

2. Fill the reservoir with recommended hydraulic fluid,

which should be filtered before entering the reser-

voir.

3. The inlet line leading from the reservoir to the charge

pump must be filled before start-up. loosen the fitting

on this inlet line until oil bleeds out.

4. Start the engine and run at the lowest possible RPM.
5. as air is purged from the unit, the oil level in the res-

ervoir will drop and bubbles may appear in the fluid.

Refill the reservoir as necessary.

6. Run the unit in both directions for several minutes until

any remaining air is purged from the unit. Refill the

reservoir as necessary.

Do not start engine unless pump is in neutral or detent

position on the cable.

Warning

Section

hYdraulic feed

4

Handle pressurized hydraulic fluid carefully. Escaping

pressurized hydraulic fluid can have sufficient force to

penetrate your skin causing serious injury. This fluid

may also be hot enough to burn. Serious infection or

reactions can develop if proper medical treatment is not

administered immediately.

cauTion

7. Check to make sure the feed roller stops when the

control arm is in the neutral position. Adjust the cable

clevis or anchor if the feed roller doesn't stop.

8. Shut down the engine, check for and correct any

fluid leaks, and check the reservoir level. add fluid

if necessary. The hydrostatic pump is now ready for

operation.