Spark for

Revs

This option represents the number of spark signals for every

engine revolution. A two-stroke engine has one spark signal per

revolution, while a four-stroke engine has a spark every two

engine revolutions.

To set the Spark for Revs, after having entered the

CONFIGURATION MODE, push MENU/<< until you see

SPARK FOR REVS

Then push MEM to enter EDIT MODE and use MENU/<< or >>

to scroll between three standard values: x1, x2 and /2.

The most common setting for two-stroke, one cylinder

karting engines is x1.

Press MEM to save the changes or VIEW to discard the

changes.

Temperature

measure unit

This function sets the temperature unit; choose between

Celsius [°C] or Fahrenheit [°F] degrees.

To run this function, after having entered the CONFIGURATION

MODE, push MENU/<< until you see

FAHRENHEIT/CELSIUS

Then push MEM to enter EDIT MODE and use button

MENU/<< until you see the proper unit, and confirm it pushing

MEM. Press VIEW to discard the changes.

The °C or °F symbol will appear on the left of the display.