Web guy - staking guidelines, Assemble first beam – Anchor NAVI-TRAC 40 WIDE GABLE-END User Manual
Page 9

9
ST
AKE-OUT
DIST
ANCE =
UPRIGHT
HEIGHT
WEB GUY - STAKING GUIDELINES
REQUIRED DISTANCE OUT BETWEEN FRAME UPRIGHTS
AND STAKE LINE IS EQUAL TO THE UPRIGHT HEIGHT.
(FOR EXAMPLE, 8’ UPRIGHT = 8’ STAKE-OUT DISTANCE.)
42” Stake driven through stake plate.
Stake must be driven into ground as
far as possible. (1) per upright as
shown for Gabled End Units.
(1) 30” Stake through
base plate. Drive into
ground as far as possible.
1
3
6
5
MCW
R21-9
U8
BHW
XRB FOR
(X-CABLED
BEAMS ONLY)
MAKE CONNECTIONS IN NUMBER SEQUENCE
SHOWN. STAKE PLATES BEFORE ERECTING.
7
8
9
10
B3
GRW
B4
17
16
15
14
13
12
11
18
(B3 FOR USE ON MIDDLE
BEAMS ONLY. NOT USED
WITH GABLED END FRAMING.)
USE CROSS CABLE AS AN INSTALLATION
TOOL TO SQUARE FIRST BEAM BEING
RAISED. OPTIONAL ON OTHER BEAMS,
DEPENDING ON TERRAIN. NOT REQUIRED
FOR FINAL 40’ CONFIGURATION.
CAUTION: BRACES
REQUIRED TO AVOID
FRAME DAMAGE!!
ASSEMBLE FIRST BEAM
RW ON MID BEAMS, RWE ON END BEAMS
(1) STAKE PER
BASE PLATE
(1) STAKE PER
BASE PLATE
2
4