Hcsphe, Spheri, L calc – APG DCR-1006A user manual User Manual
Page 24: Horizontal cylinder with hemispherical ends), Sphere), Linear calculation)

DCR-1006A Ultrasonic Controller
Rev. A1, 2/14
24
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
HCSPHE
(Horizontal Cylinder with Hemispherical Ends)
Parameters:
FULL d (Full Distance)
EMPTYd (Empty Distance)
LENGTH (Tank Length)
dIAMET (Tank Diameter)
*ENd RA (End Radius)
*set to 0 for flat ended tanks.
Diameter
Length
Empty
Distance
End
Radius
Full
Distance
SPHERI
(Sphere)
Parameters:
FULL d (Full Distance)
EMPTYd (Empty Distance)
dIAMET (Tank Diameter)
Empty
Distance
Diameter
Full
Distance
L CALC
(Linear Calculation)
Applies a conversion multiplier to the level reading (based on the selected
Units; inches, feet, meters).
Example: suppose the product in a tank weighs 206.25 pounds per inch of
level. Assuming the Units are set to inches, the Multiplier would be 206.25
Parameters:
FULL d (Full Distance)
EMPTYd (Empty Distance)
L MULT (Multiplier)