7

2.5 Pump Pressure

This lift incorporates a unique, positive displacement pump. Therefore, standard factory models of
same manufacture cannot replace it.

Pump can operate efficiently at intermittent pressures up to 3200 PSI and continuous duty to 2500
PSI. Factory installed safety relief valve in pump is factory-set to stay within parameters of pump and
lift requirements.

2.6 Lift Duty

Autoquip standard lifts typically include intermittent duty motors and are designed to “cycle” (one
complete “up” and one complete “down” lift operation) no more frequently than every two minutes – or
approximately 60,000 times (cycles) per year. This is considered “normal” duty.

It is the responsibility of the user to notify Autoquip whenever a specific application is likely to demand
“above normal” duty from lift. Above normal duty typically requires supplemental design features to
enhance serviceable life of lift and to avoid loss of warranty.