Routine maintenance, Notice – Autoquip COMPACT LIFT User Manual

Page 25

Advertising
background image

25




Annual Inspection (1000 hours of operation):
 Change hydraulic fluid and clean reservoir as needed. Always use clean fluid.

Never return fluid from drip pans, pit, etc. back to reservoir. Dispose of and handle
used fluid as a hazardous material.

 If noise or vibration has been noticed, remove lift cylinder pins, pivot pins, and

roller bearings. Inspect for wear and replace as necessary.

 Inspect all hydraulic hoses, replace any that show signs of chafing or leaking.

 Replace all filters.

 Check for permanent mechanical deformation.

OIL REQUIREMENTS

Follow the recommendations below that apply to the circumstances most similar to your
installation.

Environment (Ambient Temperature)

Recommended Oil

Indoor locations with variable temperatures:
30 - 100 degrees F

5W 30 or 5W 40 Multiviscosity Motor Oil

Indoor locations with constant temperatures:
60 - 80 degrees F

Permissible to use SAE 20 Motor Oil

Outdoor locations: 30 - 120 degrees F

5W 30 or 5W 40 Multiviscosity Motor Oil

Outdoor locations: 10 degrees F below 0 to
100 degrees F

5W 20 or 5W 30 Multiviscosity Motor Oil

Cold Storage Warehouse: 10 - 40 degrees F

Contact local Autoquip Service Rep.

NOTE: All oils above are detergent type.

OIL CAPACITY

Oil capacity varies from one model to the next, between 2 quarts & 2 gallons.

NOTICE !

Use approved fluids only! Use of unauthorized fluids may
cause damage to seals and hosing.

DO NOT USE:

 Automatic Transmission Fluid (ATF)

 Hydraulic Jack Oil

 Hydraulic

Fluids

 Brake

Fluids

ROUTINE MAINTENANCE

Advertising