General maintenance – Autoquip COIL TRANSFER CARS User Manual
Page 23

23
15. Restore the oil level.
16. Loosen the bleeder plug at the top end of the ram casing and operate the pump to
remove trapped air from the ram. When clear oil appears, tighten the plug and
raise the lift slightly to remove the maintenance locks.
17. Lower the lift completely and hold the “DOWN” button for 30-40 seconds to allow
air in the lines to bleed back into the tank.
18. Cycle the lift 10 – 15 times.
19. Check the oil level.
20. Clean the oil fill breather cap.
21. Clean up any debris and/or spilled oil from the area.
NOTE: Depending on experience, the job should take 1 – 2 hours.
PIPE THREAD SEALANT
Loctite PST #567 pipe thread sealant or equivalent is recommended. Do not use
Teflon tape. Tape fragments can cause malfunctioning of the hydraulic system.
GENERAL MAINTENANCE