background image

DANGER

Failure to comply with these Warnings and Instructions

may result in an explosion or fire that may cause

property damage, serious personal injury or death.

PELIGRO

Si no se cumplen estas advertencias e instrucciones,

se pueden producir una explosión o un incendio que

pueden causar daños materiales, lesiones personales

graves o la muerte.

ADVERTENCIA

• Para gas LP (propano líquido) únicamente.
• Lea todas las instrucciones antes de instalar y usar.
• La desconexión o instalación de componentes y la prueba de fugas

deben realizarse únicamente al aire en un área bien ventilada.

• NO modifique el componente. Si el componente no calza, devuélvalo

al lugar de compra original.

• NO use el componente si este se encuentra dañado. Si estuviera

dañado, devuélvalo al lugar original de compra.

• NO use el artefacto hasta que se finalice la prueba de fugas y se

corrija cualquier fuga presente.

INsTALLATION GuIDELINEs
1. Remove old connection from the appliance regulator by turning it in a

counter-clockwise direction.

2. Clean all foreign debris and material from the female thread of the

appliance regulator.

3. Apply Teflon

®

tape to the male ¼” NPT thread prior to installation.

4. Install the male ¼” NPT thread to the appliance regulator by turning

clockwise. Do not cross thread.

5. Tighten the male ¼” NPT thread to the appliance regulator by only

using the proper size wrenches.

6. Leak test the connection before use.

WARNING

When leak testing the connection:
• Conduct leak test outdoors in a well ventilated area.
• Do not smoke.
• Do not use or permit sources of ignition in the area while conducting

a leak test.

• Do not use matches, lighters or flame to check for leaks.
• Do not use the appliance until any leaks are corrected.

PAuTAs DE INsTALACIóN
1. Quite la conexión vieja del regulador del artefacto haciéndola girar

hacia la izquierda.

2. Limpie todos los desechos y materiales extraños de la rosca hembra

del regulador del artefacto.

3. Aplique cinta de Teflon

®

a la rosca macho de ¼ pulg. (6.4 mm) NPT

antes de instalarla.

4. Instale la rosca macho de ¼ pulg. (6.4 mm) NPT en el regulador del

artefacto haciéndolo girar hacia la derecha. No fuerce la rosca.

5. Ajuste la rosca macho de ¼ pulg. (6.4 mm) NPT al regulador del

artefacto usando únicamente las llaves de tamaños correspondientes.

6. Compruebe que no existan fugas en la conexión antes de usar.

ADVERTENCIA

Cuando realice la prueba de fugas en la conexión:
• Realice la prueba de fugas al aire libre en un área bien ventilada.
• No fume.
• No use ni permita fuentes de ignición en el área mientras realiza una

prueba de fugas.

• No use fósforos, encendedores ni llamas para verificar si hay fugas.
• No use el artefacto hasta que se corrija cualquier fuga existente.

WARNING

• For LP-Gas Only.
• Read all instructions prior to installation and use.
• Disconnecting or installation of components and leak testing should

take place outdoors in a well ventilated area only.

• DO NOT make modifications to the component. If the component

does not fit, return to the original place of purchase.

• DO NOT use component if damaged. If damaged return to the original

place of purchase.

• DO NOT use appliance until leak testing is complete and any leaks

are corrected.

LEAk TEsTING
1. Before lighting your appliance, check for leaks by applying a mild

soapy water solution to all connections. Slowly open the cylinder
valve and check for leaks. The appearance of bubbles indicates
a leak.

2. Repair any leaks prior to lighting your appliance. If you cannot stop a

leak by additional tightening of the connections, shut off the LP-Gas
supply at the cylinder valve and have an LP-Gas service person make
the needed repairs.

WARNING

• Materials used in the construction of this device may contain brass

(which may contain lead), a chemical known to the State of California
to cause cancer, birth defects, or other reproductive harm.

• Combustion byproducts produced when using this device contain

chemicals known to the State of California to cause cancer, birth
defects or other reproductive harm.

PRuEbA DE fuGAs
1. Antes de encender el artefacto, verifique que no haya fugas aplicando

una solución de agua jabonosa a todas las conexiones. Abra
lentamente la válvula del cilindro y verifique que no haya fugas. La
aparición de burbujas indica una fuga.

2. Repare todas las fugas antes de encender el artefacto. Si no puede

detener la fuga ajustando más las conexiones, cierre el suministro de
gas LP en la válvula del cilindro y pídale a un técnico de servicio de
gas LP que realice las reparaciones necesarias.

ADVERTENCIA

• Los materiales utilizados en la construcción de este dispositivo

pueden contener latón (que a su vez puede contener plomo), un
producto químico que el estado de California ha determinado que es
cancerígeno, produce defectos congénitos o produce otros daños al
sistema reproductivo.

• Los productos secundarios de la combustión que se producen al

usar este dispositivo contienen productos químicos que el estado
de California ha determinado que son cancerígenos o que producen
defectos congénitos u otros daños al sistema reproductivo.

2

3

4

5

6

7

8

9

10

11

12

Replacement acme nut

INsTRuCTION MANuAL

GFA-100

DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

www.bernzOmatic.com

tueRca acme de Reemplazo

MANuAL DE INsTRuCCIONEs

GFA-100

NO DESECHE ESTAS ADVERTENCIAS E INSTRUCCIONES

www.bernzOmatic.com

331377 11.04.11

200 Old Wilson Bridge Road
Columbus, OH USA 43085
(866) 928-2657
worthingtoncylinders.com

200 Old Wilson Bridge Road
Columbus, OH EE.UU. 43085
(866) 928-2657
worthingtoncylinders.com

COMPONENTs

¼” MAlE
NPT THREAD

COUPlING
NUT

COMPONENTEs

ROSCA MACHO
DE ¼ PUlG.
(6.4 MM) NPT

TUERCA DE
ACOPlAMIENTO

Advertising