10

3. Wire burner

Code compliance

The burner/appliance installation must comply with codes listed on page
2 and any other locally applicable codes.

General wiring requirements

Read and follow the guidelines in this manual. Failure to

comply could result in severe personal injury, death or
substantial property damage.

Electrical shock hazard — Disconnect electrical supply to the
burner before attempting to service. Failure to comply could
result in severe personal injuiry, death or substantial property
damage.

Figure 6 Ladder wiring diagram

Electrically ground burner — The burner must be grounded

in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70 (in
Canada, the Canadian Electrical Code Part 1, C.S.A. Standard
C22.1.)

Label all wires before removing for servicing. Wiring errors
could result in unsafe appliance/burner operation.

Read appliance manufacturer’s instructions completely before

wiring burner.

Check polarity carefully. If hot and neutral wires are reversed
at appliance power source, the control will not operate.

If replacing any of the wire supplied with the burner, use
minimum #14 AWG 125°C or better.