Calibration program – COATS 1100 Series Balancer User Manual

Page 21

Advertising
background image

Important: Always read and follow instructions.

• 17

Calibration Program

Important: Be sure to use the correct calibration

weight amount: a 4-ounce calibration weight with the

ounce option or a 100-gram calibration weight with the

gram option activated. Be sure to deactivate the Round

Off option.

Machine Calibration

For machine calibration, proceed as follows:
1.

Mount a 14, 15, or 16-inch steel tire/wheel assem-

bly on the balancer. A balanced tire/wheel is required.

Note: Position wheel so that no weights are on either

flange at the top-dead-center location. Turn the machine

OFF then ON.

2.

Press and hold Calibration key for three (3) seconds

to select Machine Calibration mode.

3.

Press “D” key to enter the D (diameter) dimension.

Press the Up and/or Down arrow key to adjust numbers.

A valid data entry is either “14”, “15”, or “16”.

4.

Press the Function key.

5.

Lower the hood and press the START key to begin

the measurement cycle.

6.

After the tire/wheel stops spinning, raise the hood.

7.

Rotate wheel until the Outboard center bar blinks.

Attach calibration weight (either 4-ounce or 100 gram) to

the outboard flange at top-dead-center.

Figure 24 - Calibration Weight On Outboard Flange At Top-
Dead-Center

8.

Lower the hood and press the START key to begin

the measurement cycle.

9.

After the tire/wheel stops spinning, raise the hood.

10.

Rotate wheel until the Inboard center bar blinks.

Move and attach the 100-gram calibration weight to the

inside flange at top-dead-center.

Important: It is critical that the inner weight be placed

accurately to achieve proper calibration. If the calibration

weight is not moved from the outside flange directly

across to the inside flange, an inner weight placement

error will occur and the calibration will be “failed”.

Figure 25 - Calibration Weight On Inboard Flange At Top-Dead-
Center

11.

Lower the hood and press the START key to

begin the measurement cycle.

12.

After the tire/wheel stops spinning, machine dis-

plays “100, END CAL”.. Machine Calibration is complete.

13.

Press FUNCTION to exit.