Instructions when using nitrogen as infl ation gas – COATS Kit 85607770 Tire Inflation Cage User Manual

Page 8

Advertising
background image

8 •

COATS

Instructions When Using Nitrogen

As Infl ation Gas

Program Setup For Nitrogen

Manufacturer Recommended

for

Standard Air

BL2 - 100 (no purge)
RPT - 0 (no repeats)
BL1 - 100 (no defl ation)

Manufacturer Recommended

for

N2 Parameters

BL2 - 40 (40% purge)
RPT - 0 (no repeats)
BL1 - 0 (full defl ation)

Parameter Definitions:

BL2: Purging N2 percentage or Bleeding/Purge %

0 – 100, 100 = no purge

After first fill cycle is complete, the unit deflates

tire to set percentage (BL2) of the set pressure.

RPT: Number of N2 Purges (BL2 parameter). The unit

repeats N2 purges according to this setting.

RPT set to 0 = no repeat, 1 purge only

BL1: First deflation percentage

0 – 100, 100 = no deflation

Prior to the first fill cycle, the unit deflates the

tire to set percentage (BL1) of the set pressure.

Example: If tire has 100 PSI and BL1 is pro-

grammed to 10 (%), the unit deflates the tire to

10 PSI first and then starts the fill cycle.

To change nitrogen parameters, access the program

N2 parameters mode:

1.

Turn power to the inflator gauge off and then power

it back on. The inflator gauge will display 0000, 1111,

2222 up to 9999.

2.

A short beep sounds just after inflator gauge

displays 9999. Push the

button to enter into

program N2 parameters mode. The inflator gauge will

display Adu.

Note: If the unit does not display Adu, then it is in

user mode. Repeat steps 1 - 2 until Adu is displayed

were the unit is in the program N2 paramenters mode.

In program N2 parameters mode, the inflator gauge

displays the following:

1.

BL2 displays on the LCD followed by the purge

percentage number that is programmed.

Press

or

button to set the BL2

parameter setting. The display amount advances in 5%

increments from 0 to 100.

Push the

button to confirm and advance to

the next field.

2.

RPT displays on the LCD followed by the number

that is programmed.

Use the

button to change repeat function to

desired parameter.
0 = no repeat, 1 = 1 repeat, etc.

Push the

button to confirm and advance to

the next field.

3.

BL1 displays on the LCD followed by the percent-

age number that is programmed.

Press

or

button to set the BL1

parameter setting. The display amount advances in 5%

increments from 0 to 100.

Push the

button to confirm.

Note: The unit saves the new parameters and reverts

back to user mode. The Default pressure is displayed

on the LCD.

Advertising