Notes on operation and setting, Factory setting, 3 operation and setting/adjustment – Eberspacher EasyStart Remote+ Operating instructions User Manual

Page 8

Advertising
background image

8 | VehiCLe heATeRs – TeChniCAL DOCuMenTATiOn

ADD-On uniT

An add-on unit can be e.g. a second heater or park-
ing air conditioning. Further, it is also possible to
combine a heater with a fan; the fan is then used for
air distribution in the vehicle interior.
A heater and the add-on unit can be operated simul-
taneously or independently of each other.

plEasE NOtE!

The number of symbols and displays differs depend-
ing on the installed heater and feature options.

factOry sEttiNg

pROgRAM / pReseLeCTiOn (for all heaters)

ƒ

Weekday group Mon – Fri

ƒ

Departure time 07:00

ƒ

Language De

ƒ

Time format 24 h

ƒ

Operating time for preselection (preset) 30 min-
utes

AiR heATeRs

ƒ

Continuous heating operating time

ƒ

setpoint temperature 21 °C

WATeR heATeRs

ƒ

Operating time 30 minutes

ƒ

automatic operating time calculation OFF

3 OpeRATiOn AnD seTTing/ADjusTMenT

seTTing The OpeRATing TiMe

The operating time can be set individually using the

or

button. setting range of the operating

time min. 10 – max. 120 minutes, the input is made
in 1 min. intervals. Continuous heating mode is addi-
tionally possible for air heaters.

heATing On WiTh LOngpRess

The heater is switched on immediately. An add-on
heater is

not switched on at the same time.

heATing OFF WiTh LOngpRess

if a heater and an add-on unit is in operation both are
switched off.

NOtEs ON OpEratiON aNd sEttiNg

VenTiLATiOn OpeRATing TiMe

VenTiLATiOn mode is not possible with all heater
types (see the Technical Description of the heater for
details).

TeMpeRATuRe sensOR
A temperature sensor, included in the scope of sup-
ply, must be connected for the temperature query
inside the vehicle for water heaters. in the case of air
heaters it is not necessary to install the temperature
sensor supplied, as the temperature sensor installed
in the heater for temperature query can also be used
to determine the interior temperature.

Advertising