Digital output interface – a mode, Analog input – ElmoMC Gold Line Digital Servo Drives-Gold Drum HV User Manual
Page 98

Gold Drum HV Installation Guide (EtherCAT and CAN)
Technical Specifications
MAN-G-DRUMHVIG-EC (Ver. 1.202)
98
5.5.5.
Digital Output Interface – A Mode
Feature
Details
Option applicable
A
Type of output
Optically isolated Sink
Maximum supply output (VDD)
30 V
Max. output current
I
out
(max) (V
out
= Low)
I
out
(max) ≤ 300 mA for Output 1
I
out
(max) ≤ 150 mA for Outputs 2 to 4
VOL at maximum output voltage
(low level)
V
out
(on) ≤ 0.3 V
R
L
The external R
L
must be selected to limit output
current to no more than 300 mA (Output 1) or
150 mA (Outputs 2 to 4).
Executable time
0 < T < 250 µsec
Figure 46: Digital Output Schematic for A Option
5.5.6.
Analog Input
Feature
Details
Maximum operating differential voltage
± 10 V
Maximum absolute differential input voltage
± 16 V
Differential input resistance
3.74 kΩ
Analog input command resolution
14-bit