Object 0x605b: shutdown option code – ElmoMC CANopen DSP 402 Implementation Guide User Manual
Page 38

CANopen DSP 402 Implementation Guide
MAN-CAN402IG (Ver. 1.2)
32
Data description:
Value Description
-32,768…-1 Manufacturer
specific
0
Disable drive function
1
Slow down on slow-down ramp and then disable the drive
2
Slow down on quick-stop ramp and then disable the drive
3
Slow down on current limit and than disable the drive (tq
mode only)
4 Not
supported
5
Slow down on slow-down ramp and stay in QUICK STOP
7
Slow down on the current limit and stay in QUICK STOP
(tq mode only)
8 Not
supported
9…32,767 Reserved
An attempt to set an unsupported value causes the transmission of abort code
0609 0030: Value exceeded.
Object 0x605B: Shutdown option code
This parameter determines which action should be taken in case of the transition:
OPERATION ENABLE => READY TO SWITCH ON.
Object description:
Index 605Bh
Name
Shutdown option code
Object code
VAR
Data type
INTEGER16
Category Optional
Entry description:
Access Read/write
PDO mapping
No
Value range
INTEGER16
Default value
0