Environmental conditions – ElmoMC AC Input Digital Servo Drives-Bassoon User Manual
Page 54

Bassoon Installation Guide
Technical Specifications
MAN-BASIG (Ver. 1.502)
54
Feature
Units 1/230
3/230
6/230
current
Sinusoidal continuous RMS current
limit (Ic)
A
0.7
2.3
4.2
Peak current limit
A
2 x Ic
Supplied with heat sink
No
#2 (fins)
#4 (fins and fan)
Built-in shunt (peak power)
W
400
Weight
g (oz)
350 g (12.35)
490 g (17.28)
505 g (17.81)
Dimensions
mm (in)
105 x 44 x 76
(4.13" x 1.73" x 3")
105 x 56 x 76
(4.13" x 2.20" x 3")
105 x 66.5 x 76
(4.13" x 2.60" x 3")
Digital in/Digital out/Analog in
6/2/1
Mounting method
Wall mount (Bookshelf) or DIN rail
4.3. Environmental Conditions
Feature
Details
Operating ambient temperature
according to IEC60068-2-2
0 °C to 40 °C (32 °F to 104 °F)
Storage temperature
-20 °C to +85 °C ( -4 °F to +185 °F)
Maximum non-condensing humidity
according to IEC60068-2-78
95%
Maximum Operating Altitude
2,000 m (6562 feet)
Mechanical Shock
according to IEC60068-2-27
15g / 11ms Half Sine
Vibration
according to IEC60068-2-6
5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G