Digital output interface, Max) io vol vcc r – ElmoMC AC Input Digital Servo Drives-Bassoon User Manual
Page 64

Bassoon Installation Guide
Technical Specifications
MAN-BASIG (Ver. 1.502)
64
4.8.2.
Digital Output Interface
Feature
Details
Connector Location
Type of output
•
Optically isolated
•
Open collector and open emitter
Maximum supply
output (Vcc)
30 V
Maximum output
current
Io (max) (Vout =
Low)
Iout (max) ≤ 10 mA
VOL @ maximum
output voltage (low
level)
Vout (on) ≤ 0.3 V + 0.02 * Iout (10 mA)
RL
External resistor RL must be selected to
limit output current to no more than 10
mA.
(max)
Io
VOL
Vcc
R
L
−
=
Executable time
If output is set to one of the built-in
functions — Home flag, Brake or AOK —
execution is immediate upon detection:
0 < T < 4 x TS
If output is set to General output and is
executed from a program, the typical
time is approximately 0.5 msec.
Rout = 20Ω
33v
OUTput Ret(i)
OUTput (i)
HAR0061A
Figure 33: Digital Output Schematic
Digital