4.1.7.
Built-In Protection
•
Software error handling
•
Abort (hard stops and soft stops)
•
Status reporting
•
Protection against:
Shorts between motor power outputs
Shorts between motor power outputs and power input/return
Failure of internal power supplies
Over-heating
Continuous temperature measurement. Temperature can be read on-the-fly, and a
warning can be initiated x degrees before temperature disable is activated.
Over-/under-voltage
Loss of feedback
Following error
Current limits
4.1.8.
Status Indication
•
By software/composer interface during continuous communication
•
Output for a bi-color LED - to be implemented via user external LED.
4.1.9.
Automatic Procedures
•
Commutation alignment
•
Phase sequencing
•
Current loop offset adjustment
•
Current loop gain tuning
•
Current gain scheduling
•
Velocity loop offset adjustment
•
Velocity gain tuning
•
Velocity gain scheduling
•
Position gain tuning