Sensor3 CE Rack (ESR3) Installation Manual

Running DMX Cable to Racks

Step 1:

Remove the desired top, bottom or side conduit knockout

from the first rack on the left or right of the group of racks. See

Figure 20:Side data knockouts

for knockout locations.

Step 2:

Remove the 25mm side data conduit knockouts between the

first rack and the other racks in the group.

Step 3:

Attach control cable conduit in the first knockout hole and the

knockouts between the remaining racks.

Step 4:

Pull DMX512 cables through the conduit connection on the first rack and through

the connections between racks until the cable reaches the last rack in the group.

Leave 250-300mm of slack at each rack’s backplane.

DMX Termination - Screw Terminals

Step 1:

Terminate the cable(s) as shown below

using the termination kit included with

the rack (in the rack door). Refer to the

guide included with the kit for detailed

termination instructions.

Step 2:

Connect the DMX header to the

relevant socket on the rear of the

backplane.

DMX Termination - IDC Connection

Step 1:

Terminate the cable as shown below

using an IDC termination kit. Note that

an IDC termination kit is not included

N o t e :

If the system includes a Panic circuit, stations or Remote Tracking Selection, pull

the necessary wires with the data cables to all required racks.

N o t e :

Using side knockouts for data cable conduit between racks is

recommended because it provides the most direct route

between CEM3 backplanes. You can use the top and bottom

openings if desired.

N o t e :

If you are installing control cable in racks that are joined

together, install IP20 rated conduit bushing into the knockout

holes between the racks

N o t e :

Only one screw header is supplied with

the rack. You may use the header to

terminate DMX A and DMX B to “PASS-

THRU” if needed.

Figure 20: Side

data knockouts

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

COM

n/c

n/c

n/c

n/c

n/c

n/c

n/c

n/c

n/c

n/c

Data + (Red)

Data - (Black)

From source

DMX A

If daisy-chaining to
another rack or
DMX device...

COM

Data + (Red)

Data - (Black)

From source

DMX B

If daisy-chaining to
another rack or
DMX device...

Figure 21: Stranded DMX Connection