16 read flag, 17 read_mfk_param, Read flag – EUCHNER AS-i 3.0 Command Interface User Manual
Page 61: Read_mfk_param

AS-i 3.0 Command Interface
Commands of the Command Interface
Subject to reasonable modifications due to technical advances
Id.-No.: 102875 Issue date - 3.12.2007
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen
Tel. +49/711/7597-0, Fax +49/711/753316
61
4.6.16
Read Flag
Use this command to read out the flags of a control program.
The control program of devices with control functions takes on data from the su-
perior fieldbus interface.
4.6.17
READ_MFK_PARAM
Use this command to read multiple commands of a SEW MFK21 slave.
Response
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
85
16
2
T
result
Request
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
86
16
2
T
–
circuit
3
introductory address
4
number n
Response
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
86
16
2
T
result
3
data 1
...
n
data n
Request
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
59
16
2
T
–
circuit
3
slave
4
index high
5
index low
6
number (n)
Response
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
59
16
2
T
result
3
prm byte (index)