No result because toggle bit = 0.
Set the toggle bit:
The current configuration data has been written.
3. Set master to protected mode
No result because toggle bit = 0.
Response
Byte 1
00
hex
(or old values)
Byte 2
00
hex
(or old values)
…
…
Byte 12
00
hex
(or old values)
Request: STORE_CDI
Byte 1
07
hex
(STORE_CDI)
Byte 2
80
hex
(T = 0, master 1, single master)
Byte 3
00
hex
…
…
Byte 12
00
hex
Response
Byte 1
00
hex
Byte 2
80
hex
(T = 1, result = 0)
Byte 3
00
hex
(or old values)
…
…
Byte 12
00
hex
(or old values)
Request: SET_OP_MODE
Byte 1
0C
hex
(SET_OP_MODE)
Byte 2
00
hex
(T = 0, master 1, single master)
Byte 3
00
hex
(= protected mode)
Byte 4
00
hex
…
…
Byte 12
00
hex
Response
Byte 1
00
hex
(or old values)
Byte 2
00
hex
(or old values)
…
…
Byte 12
00
hex
(or old values)