No result because toggle bit = 0.
Set the toggle bit:
Master is now in configuration mode.
Result = 0
⇒ No error, for other result codes see chapter 4 Commands of the
Command Interface, page 12 "Commands of the Command Interface".
2. Write the actual slave configuration to the master
Response
Byte 1
00
hex
(or old values)
Byte 2
00
hex
(or old values)
…
…
Byte 12
00
hex
(or old values)
Request: SET_OP_MODE
Byte 1
0C
hex
(SET_OP_MODE)
Byte 2
80
hex
(T = 1, master 1, single master)
Byte 3
01
hex
(= config mode)
Byte 4
00
hex
…
…
Byte 12
00
hex
Response
Byte 1
0C
hex
Byte 2
80
hex
(T = 1, result = 0)
Byte 3
00
hex
(or old values)
…
…
Byte 12
00
hex
(or old values)
Request: STORE_CDI
Byte 1
07
hex
(STORE_CDI)
Byte 2
00
hex
(T = 0, master 1, single master)
Byte 3
00
hex
…
…
Byte 12
00
hex