1 connecting a safety contactor, Connecting a safety contactor, Asi+ asi – EUCHNER AS-i Safety Output Relay with four standard inputs User Manual
Page 21: As-i safety output relay with four standard inputs

AS-i Safety Output Relay with four standard inputs
Installation Instructions
Subject to reasonable modifications due to technical advances
Id.-No.: 103573
Issue date - 28.5.2009
EUCHNER GmbH + Co. KG
21
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
8.3.1
Connecting a safety contactor
ASI+
ASI–
I
–
I
1
1.13
ASI
+
I
+
I
2
1.14
ASI
–
I
+
I
3
1.23
NC
I
+
1.Y1
1.24
NC
ADDR
RUN
PRG
N
K2
K1
L1 L2 L3
Motor
1.Y1
1.14
1.13
I+
L
Adressierung ist auch mit Handadressiergeräten möglich // In addition, a hand-held
addressing device can be used to program the address // L'adressage est possible
également avec un dispositif d’adressage manuel // L’indirizzamento è anche possi-
bile con un dispoitivo di programmazione manuale // El asignamiento de dirección es
también posible con el dispositivo de mano.