28
Subject to reasonable modifications due to technical advances
Id.-No.: 103573
Issue date - 28.5.2009
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
AS-i Safety Output Relay with four standard inputs
Installation Instructions
8.6
Montage
1 x 0.5 - 1.5 mm² (16AWG: min. 24/max.12)
5 ... 6 mm / PZ2
0,8 Nm
7
LB.IN
2 x (0,5 .... 1,5)
mm
2
2 x (0,5 .... 1,5)
mm
2
AWG
2 x 24 ...12
10
10
Temperature rating for cable: 60/75
o
C
Use copper conductors only
Operating temperature: 0 °C
… +55 °C
on mounting plate with 35 mm top-hat rail