Operating instructions enabling switch zsm, Technical data, Figure 1: application example – EUCHNER ZSM User Manual
Page 4

Operating Instructions Enabling Switch ZSM
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49 711 7597-0 Fax +49 711 753316 [email protected] www.euchner.com
Subject to technical modifications; no r
esponsibility is accepted for the accuracy of this information.
© EUCHNER GmbH + Co. KG 098540-05-08/11 (translation of the original operating instructions)
Figure 3: Dimension drawing, enabling switch ZSM and holder
5000
180
<79>
40
Plus/minus button
Key-operated switch
LED
Enabling switch
Stop button
DC 24 V
GND
-S1
1
2
3
Stufe
E1
0V
M
-
+
+24V
E2
E3
EUCHNER
ZS-M 09xxxx
A1
24VDC
A1
A2
S11
S10
ESM-BA2xx
S13
EUCHNER
Start
monitored
S21 S12
K1
+
S14
K2
+
13
14
23
24
Figure 1: Application example
Technical data
Parameter
Value
Material
Housing
Enabling switch
Grip/seal
PA
CR
TPE
Degree of protection
according to IEC 529
IP54
Ambient temperature
-5 ... + 60 °C
Degree of contamination
(external, according to
EN 60947-1)
3 (industrial)
Enabling switch
switching contacts
3 changeover contacts
Life
1 x 10
6
operating cycles
Utilization category
to IEC 947-5-1
(for enabling switch S4)
DC13 U
e
24V I
e
0.3A
U
e
24V I
e
1A
Short circuit protection
according to IEC 60269-1
1)
2 A gG
Weight
Approx. 1.1 kg
Cable resistance
≥ 145 W / km
Conductor cross-section
0.14 mm
2
Cable length
5 m
Rated impulse
withstand voltage
U
imp
= 1.5 kV
Rated insulation voltage
U
i
= 250 V
Rated short-circuit current
100 A
Reliability values according to EN ISO 13849-1
B
10d
1 x 10
5
1) In case of deviating cable lengths, the short circuit protection must
be dimensioned accordingly and checked.
0
2
4
6
10
20
30
40
0
a
b
1
3
2
Figure 2: Diagram of actuating force as a function of actuating travel
Actuating travel [mm]
Actuating for
ce appr
ox. [N]]