Problem

Possible Cause

Solution

6. Control valve stalled in

regeneration

a. Motor not operating

a. Replace motor

b. No electric power at outlet

b. Repair outlet or use working outlet

c. Defective transformer

c. Replace transformer

d. Defective PC board

d. Replace PC board

e. Broken drive gear or drive cap

assembly

e. Replace piston kit assembly

f. Broken piston retainer

e. Replace piston kit assembly

g. Broken main or regenerant piston

g. Replace piston kit assembly

7. Control valve does not

regenerate automatically when

REGEN

button is depressed and

held

a. Transformer unplugged

a. Connect transformer

b. No electric power at outlet

b. Repair outlet or use working outlet

c. Broken drive gear or drive cap

assembly

c. Replace piston kit assembly

d. Defective PC board

d. Replace PC board

8. Control valve does not

regenerate automatically but
does when

REGEN

button is

depressed

a. Bypass valve in bypass position

a. Put control valve in service position

b. Meter connection disconnected

b. Connect meter to PC board

c. Restricted/stalled meter turbine

c. Remove meter and check for rotation or

foreign material

d. Defective motor

d. Replace meter

e. Defective PC board

e. Replace PC board

f. Set-up error

f.

Check control valve set-up procedure

9. Time of day flashes on and off

a. Power has been out more than

two hours

a. Reset the time of day

b. The transformer was unplugged

and then plugged back into the
wall outlet

b. Reset the time of day

c. The transformer plug was

unplugged and then plugged back
into the board

c. Reset the time of day

d. The

NEXT

and

REGEN

buttons

were pressed to reset the valve

d. Reset the time of day