Silicone cable connection between ballast & fixture:
Connect the Amphenol plug coming from the lamphouse

to socket (output to lamp). Screw on the bayonet catch

(clockwise) to ensure safe connection.

Main Switch:
For normal operation & for DMX operation the main

switch should be at “ON” = 1 at all times. Should the

unit no longer react to standard DMX values, switching it

“OFF” and “ON” can reset it.

Ventilator Opening:
Make sure the ventilator openings do not become obstruct-

ed so that the free flow of air is maintained.

Note: The fan only runs when the fixture is in use and “lit”.

Hour Counter:
This serves to monitor

lamp service life. Reset

is not possible.

Lamp Installation
Make sure unit is

unplugged. Open the

milled screw at the

rear of the fixture with

a screwdriver. Pull the

lamp house back, tip-

ping it down slightly. It is

secured from falling by

the grounding cable.
(Pull out the old lamp)

and insert the new lamp without touching the quartz ele-

ment. The lamps of the fixtures are also numbered. You

have to use only the lamps and the fixtures with the same

numbers.
Due to the differences of the manufacturing of the Philips

MSR 575 HR lamp, it’s very important to pay attention

to the lamp position. You should insert the lamp only as

shown on the picture. The lamp is adjusted in that po-

sition, with the “Phillips” logo on the top (see photo).

Re-place the lamp house on the guide rails and push the

unit together.
Tighten the milled screw again with a screwdriver, until

you hear a click from the Safety switch.

Page 2 of 4

www.rosco.com

GAM Product # GL4002.15/30,25/50

METAL HALIDE 575W

YOU ARE NOW READY TO POWER UP THE UNIT.
DMX Operation
The electronic ballast takes 2 channels. Set the switch to

manual and make sure the main switch is on.

Setting the Start Address:
Use the UP and DOWN keys to set the start address.

Press MEM, while display in on, to store the new

address. If you don’t press MEM then changes are lost.

Green LED shows valid DMX is present. To avoid

unwanted light from both displays, remember they are

only on after power up and when pressing a button.

Channel 1 (start address): on/off

LI4000.01M-DMX switches on at 128 (50%).

DMX%

DMX (dec)

Lamp

0-49

0-127

Off

50-100

128-255

On

It takes about two minutes for the GAM 575W Metal

Halide lamp to reach operating temperature in which

dimming is possible.

Channel 2 (start address + 1): dimming Intensity is

regulated according to DMX from 30% to 100%

Curve is linear to achieve even dimming.

DMX%

DMX (dec)

Intensity

0-9

0-24

Minimum (30%)

10-90

25-230

Dim

91-100

231-255

Maximum (100%)