3. VERIFICATION that no shorts exist in the entire system

hazardous sparks resulting in electrical fires or flying molten metal.

CAUTION: If wiring is shorted to the frame, high current conductors can cause

prior to the actual install to verify that mounting locations are safe and practical.

amber-Johnson also recommends positioning of all mounts and equipment in the vehicle

*G

equipment (printers, modems, scanners, etc.).

3. Interconnect entire assembly and verify start-up of all components, including other

dock.

2. Insert computer into docking station and verify that the computer is operating in the

1. Make sure computer is operational by itself.

and software issues are resolved prior to installation:

Gamber-Johnson strongly advises a "bench test" be conducted to verify that all electronic

Page 3 of 8

PRE-INSTALLATION RECOMMENDATIONS

in property damage, serious injury or death.

WARNING: Failure to follow all safety precautions and instructions may result

maintenance or re-installing.

File these instructions in a safe place and refer to them when performing

Conduct a "Bench Test"

Test the docking station to ensure that it is working properly.

clear of anything that could be damaged.

After Installation

air bag.

When drilling into the vehicle, DO make sure that both sides of the surface are

1. ALL other electrical connections are made

DO NOT install equipment or route wiring or cords in the deployment path of any

DO NOT connect this docking station to the vehicle battery until:

During Installation

2. Mounting of ALL components are complete