General Machine Products Co., Inc

.

3. Replace the Hydraulic Fluid.

a. Clean and refit drain plug C.

b. Pour fluid through filler until it reaches the required level on sight gauge A.
c. Refit filler cap B.

Note: Use only the recommended hydraulic fluid.

Changing the Main Hydraulic Filter

(Figs. 5/6)

WARNING

Hot oil and engine components can burn you. Make sure the

engine is cool before doing this job. There may be limited fluid

spillage when the filter is removed. Clean any spillage immedi-

ately and dispose of materials in accordance with current regu-

lations.
1. Position the machine on level ground. Switch off the engine

and allow it to cool down.

2. Place a container of suitable size beneath the filter to catch

any spilt fluid.

3. Remove the three bolts A securing the lid to hydraulic filter

housing B, and remove the lid.

4. Lift out and dispose of the used filter.
5. Push the new element C firmly into place in the

filter housing B.

6. Refit the lid on the filter housing B, ensuring that

spring clip D locates between spigots E. Secure
with the three bolts A.

7. Check the hydraulic fluid level, see Checking the

Hydraulic Fluid Level.

Cleaning the Cooler

The oil cooler fins may be cleaned using low pressure compressed air. Do not attempt to

clean using a wire brush as this could damage the fins.

Gaining Access to Machine Components (Fig. 7)

To facilitate easier maintenance, the tubular frame is fitted with hinge bolts. The frame

may be moved to afford ready access to the machine components in the following man-
ner:
1. Remove and retain securing

clips (A).

2. Lift the tubular frame out of the

way of the machine components

by rotating it on bolts (B).

!

Fig. 5

Fig. 6

Fig. 7