4. OPERATING PROCEDURE

IT IS IMPERATIVE THAT ALL PERSONS USING, OPERATING OR MAIN-

TAINING THIS AFTERCOOLER BE FULLY TRAINED AND COMPETENT TO

DO SO, AND HAVE READ THE ENTIRE OPERATING MANUAL. GMP CAN-

NOT BE HELD RESPONSIBLE FOR MISUSE OF THIS EQUIPMENT.

4.1

Refer to section 5.1 for pre-usage checks.

4.2

Connect the air supply hose from the Air compressor to the aftercooler inlet us-

ing the cam and groove quick action release hose couplings, check that all the

cam and groove air hose couplings are fully locked, and the securing clips are

fitted before pressurizing the air hoses. The inlet connection on the aftercooler

from the compressor is marked input (an arrow gives the direction of com-

pressed air flow). The hose should be laid out as straight as possible to avoid

problems when pressurized. Note: Do not unlock the hose cam couplings while

the Aftercooler is pressurized.

4.3

Connect the air supply hose from the Aftercooler outlet to the cable Blowing Ma-

chine inlet using the cam and groove quick action release hose couplings, check

that all the cam and groove air hose couplings are fully locked, and the securing

clips are fitted before pressurizing the air hoses. The outlet connection on the

aftercooler to the blowing Machine is marked with output, (an arrow gives the

direction of compressed air flow). The hose should be laid out as straight as

possible to avoid problems when pressurized. Note do not unlock the hose cam

couplings while the Aftercooler is pressurized.

4.4

With the compressor running at a pressure not exceeding 12 BAR (175 P.S.I.) in

a safe condition, make sure that the pressure gauge on the filter-lubricator is

reading 7 BAR (100 P.S.I.) If it is not, adjust the knob on top of the regulator.

The regulator can be locked into position by raising the knob after adjustment.

For maximum reliability the 7 BAR (100 P.S.I.) setting should be maintained dur-

ing the blowing operation. Refer to the operator manual supplied with the air mo-

tor for further details.