Adjust the red screw adjuster on the air motor lubricator using a 4mm hex

wrench to allow one drip of oil per minute as viewed in the oiler site dome. Air

must be on and driving fan for this adjustment. This will be almost closed.

(When set, this will not require frequent adjustment)

4.6

The aftercooler system is now available for use.

4.7

Condensate from the filters will be collected in the plastic container. Dispose of

the contents in an environmentally acceptable way for oil contaminated waste.

The can should be emptied when approximately three quarters full.

Use 4mm hex wrench for adjusting

lubrication amount

Remove oil reservoir

by turning 1/4 turn

counter-clockwise to fill

Air motor adjustment knob

Advertising