General Machine Products 89016 Trailer Mounted Cable Fleeter 1/2" x 10,000' User Manual

Page 8

Advertising
background image

Page 8 of 16

b) Once the first half of the cable is placed, free the cable by releasing the Tor-
nado’s drive belts. Separate the innerducts connected in the manhole by remov-
ing the split coupling. Next, lift the Innerduct (connected to Tornado) out of the
manhole and (while feeding extra cable off the drum by hand) connect the inner-
duct to the Innerduct Clamp on the Fleeter (Fig 2).

c) IMPORTANT! Ensure sufficient cable is pulled through and placed in a loop
on the ground beside the Fleeter (Fig 2). This allows the Fleeter to be pushed
back, making room for the repositioning of the Tornado and installation of the re-
maining cable. (Fig 5)




d) Open the segments of the fixed and rotating
quadrant rollers
by releasing the toggle
clamps.








e) Having pulled a suitable length of ca-
ble off the drum and placed on the
ground beside the Fleeter, insert the
loop through the gap in the cable stor-
age cassette and clockwise around the
central frame. (Fig 3)

Fig 2

Fig 3

Advertising