Installing a glued-nailed floor system, Cantilevers for balconies, No wall load from above) – Georgia-Pacific Engineered Lumber User Manual

Page 7: Apa rated, Sturd-i-floor, Panels fastener schedules for wood i beam joists

Advertising
background image

1. Snap a chalk line across the I-joists four feet in from the wall for panel edge alignment and as a

boundary for spreading glue.

2. Wipe any mud, dirt, water, or ice from I-joist flanges before gluing.
3. Spread only enough glue to lay one or two panels at a time, or follow specific recommendations from

the glue manufacturer.

4. Lay the first panel with tongue side to the wall, and nail in place. This protects the tongue of the next

panel from damage when tapped into place with a block and sledgehammer.

5. Apply a continuous line of glue (about

1

4

-inch diameter) to the top flange of a single I-joist. Apply glue in

a winding pattern on wide areas, such as with wide flange joists and double I-joists.

6. Apply two lines of glue on I-joists where panel ends butt to assure proper gluing of each end.
7. After the first row of panels is in place, spread glue in the groove of one or two panels at a time before

laying the next row. Glue line may be continuous or spaced, but avoid squeeze-out by applying a thinner

line (

1

8

inch) than used on I-joist flanges.

8. Tap the second row of panels into place, using a block to protect groove edges.
9. Stagger end joints in each succeeding row of panels. A

1

8

-inch space between all end joints and

1

8

-inch

at all edges, including T&G edges, is recommended. (Use a spacer tool or an 8d common nail to assure

accurate and consistent spacing.)

10. Complete all nailing of each panel before glue sets. Check the manufacturer’s recommendations for

allowable cure time. (Warm weather accelerates glue setting.) Use 6d ring- or screw-shank nails for

panels

3

4

-inch thick or less, and 8d ring- or screw-shank nails for thicker panels. Space nails per the table

at right. Closer nail spacing may be required by some codes, or for diaphragm construction. The finished

deck can be walked on right away and will carry construction loads without damage to the glue bond.

aPa rated

®

Sturd-I-floor

®

Panels fastener Schedules for wood I beam Joists

(1)

(1) Special conditions may impose heavy traffic and concentrated loads that

require construction in excess of the minimums shown.

(2) Panels in a given thickness may be manufactured in more than one Span

Rating. Panels with a Span Rating greater than the actual joist spacing

may be substituted for panels of the same thickness with a Span Rating

matching the actual joist spacing. For example,

19

32

-inch-thick Sturd-I-Floor

panels 20 oc may be substituted for

19

32

-inch-thick Sturd-I-Floor panels

16 oc over joists 16 inches on center.

(3) Use only adhesives conforming to APA Specification AFG-01, or ASTM

D3498 applied in accordance with the manufacturer’s recommendations.

If OSB panels with sealed surfaces and edges are to be used, use only

solvent-based glues; check with panel manufacturer.

(4) 8d common nails may be substituted if ring- or screw-shank nails are

not available.

(5) Recommended minimum thickness for use with I-joists.
(6) Minimum nail spacing into wide face of top flange is 2( for 10d box,

12d box, 8d and smaller nails (3( for 10d and 12d common).

Installing a Glued-nailed floor System

Important Note: Floor sheathing must be field

glued to the I-joist flanges in order to achieve

the allowable spans. If sheathing is nailed

only, reduce I-joist spans in the Span Table

by 1 foot.

Span

Rating

(Maximum

Joist

Spacing)

(in.)

Panel

Thickness

(2)

(in.)

Fastening: Glue-Nailed

(3)

Nail Size

and Type

Maximum Spacing (in.)

(6)

Supported

Panel

Edges

Intermediate

Supports

16

23

32(5)

6d ring- or

screw-

shank

(4)

12

12

20

23

32(5)

6d ring- or

screw-

shank

(4)

12

12

24

23

32

,

3

4

6d ring- or

screw-

shank

(4)

12

12

7

8

8d ring- or

screw-

shank

(4)

6

12

C5

FIBERSTRONG

®

RIM CLOSURE AND DECK ATTACHMENT

Vertical load transfer of rim board = 4850 plf

Starter joist

Blocking where

required by local

codes for lateral

load transfer and/or

optional blocking for

diaphragm nailing

(3) 8d nails at corners

FiberStrong

rim board

One 2x4 min. with

1

8

9 gap

at top, fasten with 8d box

nails from each web

into 2x_.

Do not butt ends

at joist location.

FiberStrong rim board

Sheathing

Siding
Weather Barrier

CAUTION: The lag screw should be

inserted in a lead hole by turning with

a wrench, not by driving with hammer.

Over-torquing can significantly reduce

the lateral resistance of the screw

and therefore should be avoided.

8d nails

top and

bottom flange

FiberStrong rim board

1

2

9 sheathing with

weather barrier

Metal flashing–

under weather

barrier at top,

over weather

barrier at

bottom

Check local building code for appropriate detail in areas of high lateral load.

X-bridging or Wood I Beam

blocking panels

(see detail F2) required at cantilevers and

continuing for 48 on each side

of cantilevered area.

Load bearing wall

not allowed.

2x8 min. (designed by others)

nailed to backer block and web

with 2 rows of 10d nails at 69 o.c.

and clinched when possible.

Backer block depth (detail

F13) to match that of full-depth

filler blocking (detail F11).

Install backer tight to bottom

flange. Nail with 2 rows of 10d

nails at 69 o.c. and clinch.

CANTILEVER, DROPPED

29

69

48-0

9 min.

1 1/2 x L

48-0

9 max.

L

Uniform Loads Only

39

2x PT ledger attached with

1

2

9 diameter through-bolts with washers

and nuts or

1

2

9 lag screws with tip extending a minimum of

1

2

9 beyond

rim board. Capacity is 350 pounds per fastener. Bolt / lag screw

spacing to be determined by design vertical and lateral load. Lower

fastener may alternately be located in wall plate. Use high quality

caulk to fill holes and seal flashing.

Extend flashing below

2 x _ ledger and over siding.

Minimum 8d nails at 6” o.c.

toe-nail to plate, typical

Cantilevers for balconies

F5

F6

(no wall Load from above)

Installation Guide