STANDARD WIRING METHOD

USE WIRE NUTS FOR ALL CONNECTIONS

This wiring method will shut down all power to the boiler in the event of a low water condition.

OPTIONAL WIRING METHOD

USE WIRE NUTS FOR ALL CONNECTIONS

This wiring method will interrupt power only to the burner circuit in the event of a low water condition.

Step

Connect the black wire (H) and one of

the yellow wires (CUT-OFF) from the Safgard 1150 to

the hot 120 VAC lead coming from the service switch.

Step

Connect the second yellow wire

(CUT-OFF) from the Safgard 1150 to the (L1) boiler

connection.

Connect the black wire (H) from the Safgard

1150 to the hot 120 VAC lead coming from

the service switch. Connect the white wire (N)

to the neutral 120 VAC lead. Locate and

break into the burner circuit. Connect the yel-

low wires (CUT-OFF) from the Safgard 1150

in series with other limit controls as shown.

Step

Connect the white wire (N) from the

Safgard 1150 to the neutral 120 VAC lead and to the

(L2) boiler connection.