Sv switching amplifier, Technical description, Design – INFICON VSC150A absolute switch, passiv User Manual

Page 6: Vacuum switch mode of operation, 3 technical description

Advertising
background image

1.2.2 SV Switching Amplifier

Mains supply

110 to 130 VAC

220 to 240 VAC

Mains frequency

50 / 60 Hz

Power consumption

3 VA

Output relay

Switching voltage, max.

250 V

Switching current, max.

5 A

Switching capacity, max.

500 VA

Response time

30 ms

Release time

7 ms

Control circuit

24 V / 10 mA

Ambient temperature, max.

50

°

C

Weight

0.36 kg

SV Switching amplifier

Part Number 399-008

1.3

Technical Description

1.3.1 Design

The VSC150 is a diaphragm absolute pressure switch.
He can also be used as a differential pressure switch.

Within both pressure switches there is a sensing cham-
ber (1/2) and a reference chamber (1/5) separated by a
highly sensitive sealed diaphragm made of stainless
steel (1/3). A pin (1/6) in the reference chamber (1/5) is
led to the outside and insulated (1/7). The ground
connected diaphragm acts as the opposite contact.

This contact configuration is so designed that the dia-
phragm contacts the pin when it is unstressed, i. e. with
equal pressure in sensing and reference chamber.

1.3.2 Vacuum Switch Mode of Operation

For switch-point setting, the adjusting valve (1/4) bet-
ween sensing chamber (1/2) and reference chamber
(1/5) is opened and closed again when the desired swit-
ching pressure is attained. If the pressure in the sensing
chamber drops below the set reference pressure by
more than 0.1 mbar, the contact opens and energizes a
heavy-duty relay in the connected SV switching ampli-
fier.

6

6

tina42e1 (2005-03) VSC150.ga

tina42e1 (2005-03) VSC150.ga

1.2.2 SV Switching Amplifier

Mains supply

110 to 130 VAC

220 to 240 VAC

Mains frequency

50 / 60 Hz

Power consumption

3 VA

Output relay

Switching voltage, max.

250 V

Switching current, max.

5 A

Switching capacity, max.

500 VA

Response time

30 ms

Release time

7 ms

Control circuit

24 V / 10 mA

Ambient temperature, max.

50

°

C

Weight

0.36 kg

SV Switching amplifier

Part Number 399-008

1.3

Technical Description

1.3.1 Design

The VSC150 is a diaphragm absolute pressure switch.
He can also be used as a differential pressure switch.

Within both pressure switches there is a sensing cham-
ber (1/2) and a reference chamber (1/5) separated by a
highly sensitive sealed diaphragm made of stainless
steel (1/3). A pin (1/6) in the reference chamber (1/5) is
led to the outside and insulated (1/7). The ground
connected diaphragm acts as the opposite contact.

This contact configuration is so designed that the dia-
phragm contacts the pin when it is unstressed, i. e. with
equal pressure in sensing and reference chamber.

1.3.2 Vacuum Switch Mode of Operation

For switch-point setting, the adjusting valve (1/4) bet-
ween sensing chamber (1/2) and reference chamber
(1/5) is opened and closed again when the desired swit-
ching pressure is attained. If the pressure in the sensing
chamber drops below the set reference pressure by
more than 0.1 mbar, the contact opens and energizes a
heavy-duty relay in the connected SV switching ampli-
fier.

Advertising