JUMO 709010 TYA-432 thyristor power switch Data Sheet User Manual

Thyristor power switches, Technical data, Brief description

Advertising
background image

Page 1/3

JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,

36039 Fulda, Germany

Postal address: 36035 Fulda, Germany
Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

e-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM 20 2TT, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

e-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:

315-697-JUMO
1-800-554-JUMO

Fax:

315-697-5867

e-mail:

[email protected]

Internet: www.jumo.us

Data Sheet 70.9010

01.08/00073739

Technical data

Load circuit

Control

Type

TYA 432-45/25, 265

TYA 432-45/50, 530

Load voltage

24 — 265V

rms

42 — 530V

rms

Load current (maximum)

25A

rms

50A

rms

Load current (minimum)

150mA

rms

Fuse load integral limit I

2

· t (t = 10msec)

≤310A

2

· sec

≤1800A

2

· sec

Frequency

45 — 65Hz

Peak off-state voltage

650V

pk

1200V

pk

Leakage current

≤3mA

cos

ϕ (p.f.)

>0.5 at 230V

rms

>0.5 at 230V

rms

Control signal range

4 — 32V DC

Switch-on voltage

greater than 2.75V DC for TYA 432-45/25,265
greater than

3.75V DC for TYA 432-45/50,530

Switch-off voltage

less than 2V DC

Input current

≤10mA at 32V DC

Response delay

≤0.5 · cycle length

Thyristor power switches

k load currents 25A and 50A (max.)
k load voltages 265V and 530V (max.)
k control voltage 4 — 32V DC
k UL approval (E223137)

Brief description

Thyristor power switches are used for the contact-free switching of a.c. loads. A typical
application is the switching of resistive-inductive loads at high switching rates, especially
in the industrial sector, such as in the plastics packaging industry, in HVAC engineering
and in the construction of industrial furnaces.
The control and power sections are electrically isolated by optocouplers.
The control signal range is compatible with the logic outputs of JUMO controllers.
The power section operates as a zero-voltage switch, which means that it always switches
when the voltage passes through zero, irrespective of the instant of the signal change.
This prevents the generation of interference voltages. A varistor is integrated on the output
side as a protection against voltage spikes.
The input status is indicated by an LED.

TYA 432-45/50 (25), 530 (265)

Advertising