Page- 14

Each vectraLIGHT has
an RJ-11 4-pin plug at the
end of the 6’ long cable.
This 4-pin plug is inserted
in to a breakout adapter
as shown here.


The wires of the adapter can be connected using the scotch-locks. Use a
voltmeter to identify each wire, and
chose an appropriate location to snap
the scotch-lock over the wire and then
use pliers to squeeze it tight. The
small ring connector must be inserted
fully into the slot of the scotch-lock.



PROGRAMMING THE RUNNING LIGHT MODE:

Each vectraLIGHT unit is factory set for the Running Lights Mode to be
ON. If you wish to turn it OFF:

X

Apply and HOLD the brakes, then turn ignition ON (3) times quickly

Y

Leave the ignition ON the 3

rd

time

Z

As soon as the vectraLIGHTs flash, pump the brakes (5) time rapidly.


If you repeat the above procedure, it will turn the Running Light mode
back ON.

Wire Color

RJ-11

ADAPTER

WHITE

TURN SIGNAL INPUT

12-volt flash signal (high-side of bulb)

BLACK

BRAKE INPUT

12-volt from brakes (ON with brakes)

RED

POWER INPUT

Constant 12-volt with ignition ON

GREEN

GROUND Chassis

ground connection

Advertising