SERVICE (cont.)

If continuity is present as described, reconnect the

wires, the tank heater is operating properly.

If continuity is not present as described, replace the

tank heater.

NOTE- If the tank heater remains unable to heat, remove

and inspect heater for cracks in the sheath.

Removal and Replacement:

1. Remove the tank inlet fitting securing the fill

basin to the tank lid, remove fill basin and tank

inlet gasket. Set all three parts aside for reas-

sembly.

2. Disconnect the black wire on the terminal block

from the tank heater and disconnect the blue/black

wire from the limit thermostat to the control

thermostat.

3. Disconnect the black wire and the white from the

tank heater terminals.

4. Remove sprayhead and the hex nut securing

the sprayhead tube to the hood. Set aside for

reassembly.

5. Remove the eight #8-32 nuts securing the tank

lid to the tank.

6. Remove the tank lid with limit thermostat, spray-

head tube and tank heater.

7

Remove the two hex nuts securing the tank heater

to the tank lid. Remove tank heater with gaskets

and discard.

8. Install new tank heater with gaskets on the tank

lid and secure with two hex nuts.

9. Install tank lid with limit thermostat, sprayhead

tube and tank heater using eight #8-32 hex

nuts.

10. Secure sprayhead tube to hood using a hex

nut.

11. Install sprayhead.

12. Reconnect the wires to the limit thermostat,

tank heater and control thermostat. See limit

thermostat and control thermostat sections in

this manual when reconnecting wires.

13. Install fill basin, secure with tank inlet fitting and

gasket.

14. Refer to Fig. 8 when reconnecting the tank heater

wires.

P1254

FIG. 8 TANK HEATER TERMINALS